1
2
可一參考UL758做芯線老化的
3
樓主:問你的原材料供應(yīng)商,2464線材內(nèi)芯線的安規(guī)型號,依安規(guī)型號做。
4
5
是的,芯線UL公司是不做的,客戶有另要求外!
6
如果只做2464,芯線是不要求的。但是在生產(chǎn)后,UL跟蹤服務(wù)會考察你的芯線,必須是通過了UL認(rèn)證的芯線。比如您自己的認(rèn)證過的線或者使用別的廠家的UL認(rèn)證芯線即可。
參考:
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2464 Issued: 1968-05-02
Revised: 2003-05-02
Style 2464 PVC Jacketed Cable.
______________________________________________________________________________
Rating 80°C, 300 V.
______________________________________________________________________________
Insulated Labeled or complying with manufacturer's AWM Procedure
Conductors having a minimum rating of 80°C and 300 V.
______________________________________________________________________________
Assembly Two or more singles, twisted pairs of groups of twisted
singles twisted together or singles or groups of singles
may be laid parallel to form flat, oval or round cable.
Lay not specified. Barrier layer and/or fillers optional.
Manufacturer shall maintain a complete description of each
assembly. May use same or mixed AWG size.
______________________________________________________________________________
*Covering (Optional.)
______________________________________________________________________________
Shield Optional.
______________________________________________________________________________
Jacket PVC - Class 43
THICKNESS OF PVC JACKET (mils)
#Dia. of Cable Minimum
Under Jacket Minimum at any
in Inches Average point
0.700 or less 30 24
0.701 - 1.000 45 36
1.001 - 1.500 60 48
1.501 - 2.500 80 64
2.501 - 4.000 110 88
4.001 or larger 140 112
# Major diameter if cable is flat or oval.
______________________________________________________________________________
Braid Optional.
______________________________________________________________________________
Standard Appliance Wiring Material UL 758.
______________________________________________________________________________
(Continued on Page 2464A)
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subj. 758 Section 2 Page 2464A Issued: 1968-05-02
Revised: 2003-05-02
Instructions Detailed Examination of the cable assembly and jacket.
to UL Physical Properties of Jacket.
Representative Dielectric Strength Test, 1500 Volts (shielded cable only).
The designation of all Styles of the individual conductors used making up the cable assembly shall be available, and the UL Representative’s tag shall indicate if the Style is labeled or not. If they are not labeled, the appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties of Jacket.
Program (4) Heat Shock on Jacket.
(4) Cold Bend on Completed Cable.
(4) Deformation on Jacket, Class 43.
(12) Cable Flame Test on Completed Cable.
If the insulated styles are not labeled, the appropriate Follow-Up Tests shall be conducted.
______________________________________________________________________________
Marking General.
______________________________________________________________________________
Use Internal wiring or external interconnection of electronic
equipment (such as desk-type calculators, dictating
machines, or x-ray equipment).
7
8
不過為了安全起見可以參考樓上的標(biāo)準(zhǔn)做一下
9
10
11
(4) Detailed Examination.
(4) Physical Properties of Jacket.
(4) Heat Shock on Jacket.
(4) Cold Bend on Completed Cable.
(4) Deformation on Jacket, Class 43.
(12) Cable Flame Test on Completed Cable.
這個(gè)就是UL抽樣所檢測的所有項(xiàng)目與頻次了,沒有提到檢查芯線的老化性能。
但是理論上講所有的性能都要合格,才能稱為合格的產(chǎn)品。只是應(yīng)付檢查,達(dá)到以上6條要求就夠了
12
13
要做老化不然你們怎么申請的到認(rèn)證...
UL是按FUII來檢測..
14
15
應(yīng)該是要做的, 芯線可以是類似1061 或 1007 類的電子線, 送樣的話最好是用類1007的電子線, 1061很難過的.
16
17
18
19