1
查看UL STYLE 1185標(biāo)準(zhǔn)有幾點疑問:
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 1 Page 1185 Issued: May 1, 1959
Style 1185 PVC Insulated, Shielded and Jacketed Wire.
______________________________________________________________________________
Rating 80°C, 300 Volts.
______________________________________________________________________________
Conductor Copper - 30-4/0 AWG, solid or stranded, tinned or bare,
page 26
______________________________________________________________________________
Insulation Extruded PVC, Class 12
AWG Min. Avg., Mils Min. at any point Mils
30-16 15 13
15-10 30 27
9-8 45 40
7-2 60 54
1-4/0 80 72
______________________________________________________________________________
Shield Page 24.
______________________________________________________________________________
Jacket Extruded PVC, Class 12
AWG Min. Avg., Mils Min. at any point Mils
30-16 15 12
15-2 30 24
1-4/0 45 36
30-16 or lacquered braid
______________________________________________________________________________
Shield Optional, page 24.
______________________________________________________________________________
Jacket Optional, PVC Class 12,15 mils min. avg., 12 mils. min. at
any point.
_________________________________________________________________
Strandard Flexible Cord and Fixture Wire, UL62 and Thermoplastic
Insulated Wire, UL 83.
______________________________________________________________________________
Instructions Detailed examination.
to UL Physical properties - insulation and pvc jacket, Page 32.
Representative Spark Test. Page 30
______________________________________________________________________________
(Continued on 1185A)
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
Subject 758 Section 1 Page 1185A Issued: May 1, 1959
Revised: April 2, 1984
UL (4) Detailed Examination.
Counter-Check (4) Physical Properties - Insulation and PVC Jacket,
Program Page 33.
(4) Heat Shock, Page 57.
* (4) Deformation, Page 38.
(4) Cold Bnd, Page 58.
(2) Flame Test, Page 31.
______________________________________________________________________________
Marking General, Page 13.
______________________________________________________________________________
Use Internal Wiring of Appliances and Electronic Equipment.
疑問一:內(nèi)容中紅色標(biāo)記 PAGE26 PAGE24怎么看?
疑問二:UL1185是屬于UL758中的,下面strandard中怎么又是UL62 和UL83呢?
請明白人給解答一下,謝謝~!
2
難道論壇就沒個明白人嗎?
高人再現(xiàn)~~!~!
3
此貼引發(fā)的深思:
按理說這個帖子的疑問無非是怎么查看標(biāo)準(zhǔn),以及標(biāo)準(zhǔn)的基礎(chǔ)知識而已;
不知道大家是看到了不會回答還是沒看到,至今的確沒有答案;
論壇里經(jīng)?吹接懻撘恍┹^為高深的問題,確實可喜,可身為電線人如果連基本的標(biāo)準(zhǔn)識讀都難的話,我表示深深的憂慮。
4
這個問題不好意思回答.5
真不好意思回答你!!!!!!!!!!!!這種問題!!!!!!
6
樓主你這個標(biāo)準(zhǔn)是從哪里來的?
7
這是我剛剛查詢的標(biāo)準(zhǔn)!
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 1 | Page 1185 | Issued:1959-05-01 |
| Revised:2011-10-24 | |||
| Style 1185 | Single conductor using extruded non-integral jacket. | |
| Rating | 80 deg C, 300 Vac, Horizontal flame. | |||||||||
| Conductor | 30 AWG - 4/0 AWG, solid or stranded. | |||||||||
| Insulation | PVC | |||||||||
| Conductor size | Minimum average thickness | Minimum thickness at any point | ||||||||
| 30-16 AWG | 15 mils | 13 mils | ||||||||
| 15-10 AWG | 30 mils | 27 mils | ||||||||
| 9-8 AWG | 45 mils | 40 mils | ||||||||
| 7-2 AWG | 60 mils | 54 mils | ||||||||
| 1-4/0 AWG | 80 mils | 72 mils | ||||||||
| Assembly | Insulated conductor, optional shield, required jacket, optional shield, optional jacket. | |||||||||
| Shield | Optional. | |||||||||
| Jacket | Extruded PVC. | |||||||||
| Conductor size | Minimum average thickness | Minimum thickness at any point | ||||||||
| 30-16 AWG | 15 mils | 12 mils | ||||||||
| 15-2 AWG | 30 mils | 24 mils | ||||||||
| 1-4/0 AWG | 45 mils | 36 mils | ||||||||
| 30-16 AWG | or lacquered braid | |||||||||
| Outer Shield | Optional. | |||||||||
| Outer Jacket | Optional. Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. | |||||||||
| Standard | Appliance Wiring Material UL 758. | |||||||||
| Marking | General. | |||||||||
| Use | Internal Wiring of Appliances and Electronic Equipment. | |||||||||
8
9