   20276  UL要求AC與DC電壓是多少?
hnivan --- 2009-12-09 09:45:57

2

UL20276,作低電壓音頻\視頻線使用,如HDMI、電腦周邊。。。

電壓值為30V

zhengliang --- 2009-12-09 10:14:55

3

UNDERWRITERS LABORATORIES INC.               APPLIANCE WIRING MATERIAL

Subj. 758       Section 2       Page 20276       Issued:  1983-08-16

                                    Revised:  2003-06-05

 

Style 20276     Electronic Cable.

______________________________________________________________________________

 

Rating      60°C or 80°C, 30 V.

______________________________________________________________________________

 

Insulated       No. 40 AWG minimum.  Labeled or complying with AWM

Conductors      Procedure having a minimum rating of 60°C or 80°C

            whichever is applicable.

______________________________________________________________________________

 

Assembly        Consists of two or more conductors, twisted pairs,

            parallel pairs, or groups of twisted conductors or

            parallel pairs twisted together.  The conductors or

            groups of conductors may be laid parallel forming a flat,

            oval or round cable.  The lay of the insulated conductors

            are not specified.  A barrier layer and/or fillers are

            optional.  Manufacturer shall maintain a complete

            description of each assembly.  May use same or mixed AWG

            size.

______________________________________________________________________________

 

Covering        (Optional.)  A 6 mil or heavier PVC covering may be

            extruded over the conductor assembly.

______________________________________________________________________________

 

Shield      Optional.

______________________________________________________________________________

 

Jacket      PVC, Class 43.

 

                Thickness (mils)

                  Construction A       Construction B

                External Use         Internal Use

 

            #Dia. under                Minimum            Minimum

             jacket in         Minimum      at       Minimum      at

              inches__       Average   any Point   Average   any Point

 

            0.350 or less       20        17         15         12

            0.351 - 0.700       30        24         30         24

            0.701 - 1.00        40        36         40         36

            0.101 - 1.50        54        48         54         48

______________________________________________________________________________

 

Standard        Appliance Wiring Material UL 758.

______________________________________________________________________________

                                (Continued on Page 20276A)

 


UNDERWRITERS LABORATORIES INC.                APPLIANCE WIRING MATERIAL

Subj. 758       Section 2       Page 20276A      Issued:  1983-08-16

                                    Revised:  2003-06-05

 

Instructions    Detailed Examination.

to UL           Physical Properties of Jacket.

Representative 

            The designation of all Styles of the individual

conductors used making up the cable assembly shall be

available, and the UL Representative's tag shall indicate

if the Style is labeled or not.  If they are not labeled,

the appropriate Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

UL          (4)  Detailed Examination.

*Counter-Check  (4)  Physical Properties of Jacket.

*Program        (4)  Heat Shock.

*           (4)  Cold Bend.

*           (4)  Deformation.

            (12) Cable Flame Test on Completed Cable,

                 Construction A only.

            (12) Horizontal Flame Test on Completed Cable,

                 Construction B only.

 

            If the insulated Styles are not labeled, the appropriate

            Follow-Up Tests shall be conducted.

______________________________________________________________________________

 

Marking     General.

______________________________________________________________________________

 

Use         Construction A:  Internal wiring or external

            interconnection of electronic equipment in Class 2

            circuits only.

 

            Construction B:  Internal wiring of electronic equipment

            in Class 2 circuits only.

 

 