1
2
怎么沒人回答呢?難道大家都沒生產(chǎn)過這種高壓線?
3
4
標(biāo)準(zhǔn)見下面,就是沒有明確的厚度要求, 那個facing page找不到,真是郁悶!
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 3 | Page 3239 | Issued:1969-10-13 |
| Revised:2009-02-17 | |||
| Style 3239 | High-Voltage Lead Wire | |
| Rating | Maximum 200 deg C, 60000 Vdc, VW-1 flame. See facing page for temperature and voltage ratings. |
| Conductor | 24-10 AWG copper or nickel and 12-10 AWG aluminum or 27-20 AWG Resistance Wire; solid or stranded. Or 24-10 AWG solid or stranded coated high strength copper - min 90% conductivity. Aluminum conductors shall be permitted for a 90 deg C maximum operating temperature. Copper conductors may be tinned, silver or nickel plated, heat bonded or overcoated. |
| Insulation | Thermoplastic and/or Thermosetting. See facing page for details. |
| Shield | See facing page for details. |
| Covering | See facing page for details. |
| Jacket | See facing page for details. |
| Standard | Appliance Wiring Material UL 758. |
| Marking | If the outer surface of the wire is PVC, XLPVC, PVDF, PE, XLPE, XLPO, or glass or cotton braid, the wire shall be surface printed. Surface printing on other materials is optional unless otherwise noted on the facing page. 1. Recognized's Company's name or E number. 2. Plant identification, if made in more than one location. 3. DC voltage rating. 4. Temperature rating, if above 60 deg C. 5. Style No. 3239. 6. The Recognized Component Mark followed by the letters AWM or the words, Appliance Wiring Material. 7. (Optional) VW-1. |
| Use | Internal wiring of TV receivers or where the acceptability has been determined by Underwriters Laboratories. |
5
10KV 1.0
20KV 1.3
30KV 1.7
6
謝謝5樓的朋友,請問這個數(shù)值是貴公司自定的常規(guī)厚度嗎?有沒有標(biāo)準(zhǔn)支持?
7
10KV 1.0
20KV 1.3
30KV 1.7
不是吧
8