1
GB/T9330.2-2008中規(guī)定了電纜平均外徑的上限和下限,但是他們是怎么計算出來的?應該有公式計算是吧?
希望給我一個公式或者告訴我哪里有計算外徑的公式,不勝感激!
2
| 線芯排列 | K值 | ||||||
| 2芯 | 2 | 2 | 2 | ||||
| 3芯 | 3 | 3 | 2.154 | ||||
| 4芯 | 4 | 4 | 2.414 | ||||
| 5芯 | 5 | 5 | 2.7 | ||||
| 6芯 | 6 | 6 | 2.8 | ||||
| 7芯 | 1 | 6 | 7 | 3 | |||
| 8芯 | 1 | 7 | 8 | 3.3 (3.31) | |||
| 9芯 | 1 | 8 | 9 | 3.7 (3.62) | |||
| 10芯 | 2 | 8 | 10 | 4 (3.93) | |||
| 11芯 | 3 | 8 | 11 | 4.154(4) | |||
| 12芯 | 3 | 9 | 12 | 4.154 | |||
| 13芯 | 4 | 9 | 13 | 4.414(4.24) | |||
| 14芯 | 4 | 10 | 14 | 4.414 | |||
| 15芯 | 5 | 10 | 15 | 4.7(4.55) | |||
| 16芯 | 5 | 11 | 16 | 4.7 | |||
| 17芯 | 0 | 6 | 11 | 17 | 5 (4.86) | ||
| 18芯 | 0 | 6 | 12 | 18 | 5 | ||
| 19芯 | 1 | 6 | 12 | 19 | 5 | ||
| 20芯 | 1 | 6 | 13 | 20 | 5.154 | ||
| 21芯 | 1 | 7 | 13 | 21 | 5.3 | ||
| 22芯 | 1 | 8 | 13 | 22 | 5.7 | ||
| 23芯 | 2 | 8 | 13 | 23 | 6 | ||
| 24芯 | 2 | 8 | 14 | 24 | 6 | ||
這是一張成纜外徑系數表。
例:KVV3*1.5成品外徑計算:絕緣線芯直徑如2.8mm;3芯成纜系數為:2.154;絕緣厚度=1.2mm
成纜外徑=2.8*2.154=6.03
成品外徑=6.03+(2*1.2)=8.43
3
4
5
6
7
GB/T20637.2-2006附錄成C中規(guī)定了電纜平均外徑的上限和下限,電纜外徑公式計算是:
最小外徑:IF(0.97*AA5<=5,ROUND(0.97*AA5,1),IF(AND(0.97*AA5>5,0.97*AA5<=10),FLOOR(0.97*AA5,0.2),IF(0.97*AA5>10,FLOOR(0.97*AA5,0.5))))
最大外徑:IF(1.05*AB5+0.4<=5,CEILING(1.05*AB5+0.4,0.1),IF(AND(1.05*AB5+0.5>5,1.05*AB5+0.5<=10),CEILING(1.05*AB5+0.5,0.2),IF(1.05*AB5+0.5>10,CEILING(1.05*AB5+0.5,0.5))))
8
搞錯了,這是GB9331的算法。補充:AA5--假定外徑下限,AB5 --假定外徑上限
9
下限=假定直徑*0.96
上限=假定直徑*1.16
10
我也是根據樓上的那樣算的。。
在GB/T9330.3-08 6.8 上有說到。。不過是針對交聯聚乙烯絕緣控纜的,但我計算KVV時,得出的上限值和9330上的數值是一樣
11
上下限我沒有根據 都是參照標準里的 非標的話自己定