6.5 Capacitance and relative permittivity
6.5.2 Apparatus
The apparatus shall consist of
a) a capacitance bridge capable of operating at a sinusoidal or nearly sinusoidal voltage at a
frequency of 1000 Hz at 10 V or less, or 60 Hz at 3.15 kV/ mm (80 V/mil) of insulation
thickness;
b) a water tank capable of maintaining the water at the required temperature; and
c) a temperature-measuring device with an accuracy of ±1 °C.
主要儀器是電容電橋。
6.6 Stability factor
The apparatus shall consist of
a) a power factor bridge capable of operating at a sinusoidal or nearly sinusoidal voltage at a
frequency of 60 Hz at 3.15 kV/mm (80 V/mil) and 1.58 kV/mm (40 V/mil) of insulation thickness;
b) a water tank capable of maintaining the water at the required temperature;
c) a forced-circulation air oven in accordance with Clause 4.2.3 Item (i); and
d) a temperature-measuring device with an accuracy of ±1°C
主要儀器是功率因數(shù)電橋。也可以通過(guò)電容電橋測(cè)試介損再進(jìn)行計(jì)算得到功率因數(shù)。