1
弟兄門,幫我看看衰減指標(biāo)能實現(xiàn)嗎?指標(biāo)該定多少?
RG59
CONDUCTOR:
AWG 20
Stranding: Solid
Conductor Diameter: .032 in.
Conductor Material: BCCS - Bare Copper Covered Steel
INSULATION:
Insulation Material: Gas-injected FPE - Foam Polyethylene
Insulation Diameter: .144 in.
Bonded Aluminum Foil-Polyester Tape-AluminumFoil 100%
Braid
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter: .237 in.
MECHANICAL CHARACTERISTICS:
Operating
Max. Recommended Pulling Tension: 80 lbs.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CATV, CM
CEC/C(UL) Specification CM
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance 75 +/- 3 Ohms
Nom. Inductance .097 µH/ft
Nom. Capacitance Conductor to Shield 16.2 pF/ft
Nominal Velocity of Propagation 83 %
Nominal Delay 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C 44.5 Ohms/1000 ft
Nominal Outer
Nom. Attenuation :
Description Frequency (MHz) Nom. Attenuation (dB/100 ft.)
5 0.8
55 1.8
211 3.4
500 5.2
750 6.5
862 7.0
1000 7.7
1450 9.3
1800 10.3
2250 11.9
2
[cuijiude 在 2008-10-30 21:38:15 編輯過]
3
樓上的大蝦,指點(diǎn)一下吧.
謝謝
4
樓主你確認(rèn)它的單位為100ft?
5
6
5MHZ 小于3.9/100m,1000MHZ 小于27/100M保守
7
還要看BCCS的電導(dǎo)率是多少了?
8
它上面已經(jīng)給出內(nèi)導(dǎo)體電阻,導(dǎo)電率23%kaka2004:
還要看BCCS的電導(dǎo)率是多少了?
9
客戶要求永遠(yuǎn)都是苛刻的,,沒有什么過分。因為他就是你的上帝。。。
能不能做到就看你家的能力。既然有這樣的要求肯定是可以做到的。我想他們是從BELDEN網(wǎng)上復(fù)制的。
10
11
有點(diǎn)難,但總會有辦法的
12
13
單位沒有錯!
感謝各位指點(diǎn),受教了.
我考慮導(dǎo)電率為26%(放寬10%).
請教5樓的兄弟,發(fā)泡材料的選擇上有何講究?
14
我理論計算的衰減怎么也不可能滿足指標(biāo),不知道怎么回事?
我按照射頻電纜設(shè)計規(guī)范計算的,哪為仁兄幫我指導(dǎo)其中的問題.
15
請教2樓,可以做到12。5嗎?怎么做?