計算機(jī)電纜對絞節(jié)距 - 無圖版
shy --- 2008-07-04 20:54:33
1
請教計算機(jī)電纜應(yīng)根據(jù)什么原則確定對絞節(jié)距(不同絞對),對絞節(jié)距的選擇對電纜性能有何影響?計算機(jī)電纜適用于傳輸?shù)念l率是多少?
jackeyli --- 2008-07-05 10:31:54
2
絞距標(biāo)準(zhǔn)內(nèi)沒有強(qiáng)制規(guī)定,絞距小耐搖擺,絞距大成本低,但也要考慮加工的可行性,傳輸頻率依據(jù)接口來確定,如USB的傳輸頻率為480MHZ
xdjhxq --- 2008-07-05 16:35:15
3
<DIV class=xxxxAd><SCRIPT type=text/javascript></SCRIPT><SCRIPT src="http://pagead2.googlesyndication.com/pagead/show_ads.js" type=text/javascript></SCRIPT><IFRAME name=google_ads_frame marginWidth=0 marginHeight=0 src="http://pagead2.googlesyndication.com/pagead/ads?client=ca-pub-5245470700607411&dt=1215246616296&lmt=1215246616&prev_slotnames=9908240416&output=html&slotname=3492416009&correlator=1215246616203&url=http%3A%2F%2Fjqgyxcq.com.cn%2FShowPost.asp%3FThreadID%3D33545&ref=http%3A%2F%2Fjqgyxcq.com.cn%2FShowForum.asp%3FForumID%3D54&frm=0&cc=211&ga_vid=15197406762370068.1215246616&ga_sid=1215246616&ga_hid=1128921051&flash=9.0.0.296&u_h=768&u_w=1024&u_ah=738&u_aw=1024&u_cd=32&u_tz=480&u_java=true" frameBorder=0 width=200 scrolling=no height=200 allowTransparency></IFRAME></DIV>
請教計算機(jī)電纜應(yīng)根據(jù)什么原則確定對絞節(jié)距(不同絞對),對絞節(jié)距的選擇對電纜性能有何影響?計算機(jī)電纜適用于傳輸?shù)念l率是多少?
回復(fù):因國內(nèi)還沒有標(biāo)準(zhǔn)只參考BS5038英標(biāo).節(jié)距先擇對絞外徑的16倍,成纜的話和軟電纜一樣20-25倍,節(jié)距小影響的抗靜電干擾,電容平衡,電感等都有影響.計算機(jī)電纜傳輸頻率的話,樓上說的對,要看你用在什么地方.
happy2003 --- 2008-12-31 10:14:55
4
BS 5308 規(guī)定 對絞組節(jié)距小于100就可以了。