UNDERWRITERS LABORATORIES INC.              APPLIANCE WIRING MATERIAL

Subj. 758     Section 1     Page 1330        Issued:  1963-02-04

                                     Revised:  2003-04-14

 

Style 1330    Extruded Fluorinated Ethylene Propylene Insulated Wire.

______________________________________________________________________________

 

Rating     200 deg. C, 600 V.

______________________________________________________________________________

 

Conductor     Nos. 30-4/0 AWG, solid or stranded, Sec. 5. 

______________________________________________________________________________

 

Insulation    Extruded fluorinated ethylene propylene

 

                       Insulation Thickness in Mils

           Conductor Size      Minimum        Minimum at

               AWG      Average        any Point 

 

             30 - 10          20         18

              9 - 2           30         27

              1 - 4/0         45         40

______________________________________________________________________________

 

Covering      (Optional) - FEP, 10 mils or heavier or glass braid

           7 mils or heavier.

______________________________________________________________________________

 

Standard      Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed Examination.

to UL         Tensile Strength and Elongation of Insulation,

Representative       before aging.

*

           Spark Test.

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check (4)  Tensile Strength and Elongation of Insulation.

Program       (4)  Heat Shock.

           (4)  Cold Bend.

           (12) Horizontal Flame Test.

______________________________________________________________________________

 

Marking       General.

______________________________________________________________________________

 

Use        Internal Wiring of Appliances.

           In addition, the tag may also indicate the

           following: Suitable for immersion in gasoline;

           gasoline vapor; and 80 deg. C in oil.