美女胸被狂揉扒开吃奶的网站o_亚洲日韩av中文无码专区_东京热激情无码专区_久久HEZYO久综合亚洲色_欧美成人高清视频_国产精品乡下勾搭老头_欧美一级v片在线播放_成人午夜国产视频_男女猛烈无遮挡免费动态图_亚洲一区国产精品视频

電線電纜網(wǎng) > 特種電纜 > UL 1354 鐵氟龍電線請教(完整版)

UL 1354 鐵氟龍電線請教 - 無圖版

Elva --- 2007-06-20 11:53:11

1

請教各位以下詳細資料,多謝!

鐵氟龍  UL1354  36# 

鐵氟龍  UL1354  40#

鐵氟龍  UL1354  RF

[Elva 在 2007-6-20 13:36:20 編輯過]

skywish --- 2007-06-20 12:04:13

2

   也不知道你想要知道什么!鐵氟龍線UL1354偶以前是沒有做過拉!不過UL1333,1371等等!都做過!參照標準UL758,UL1581及CSA C22.2 NO.210..2可通過UL VW-1 及CSA FT1垂直耐燃測試!具有優(yōu)良熱穩(wěn)定性和機械耐磨電絕緣性能,可抗強酸強堿,耐腐蝕,耐火不燃,氧指數(shù)高,低煙無鹵,耐老化,使用標準厚度,易剝,切斷容易,額定電壓:300V,額定溫度:-80度~+150度,絕緣采用FEP聚全氟乙丙烯絕緣!以上資料僅供參考!!
Elva --- 2007-06-20 13:38:27

3

謝謝
skywish
jollyzhong --- 2007-06-23 16:59:22

4

我知道你說的是什么

1354 #40 7/0.03錫銅合金 ,絕緣0.24,27+/-1 0.03鍍錫銅,銅箔膠帶,pet膠帶 od=0.35

1354 #36 7/0.05錫銅合金,絕緣0.27,29+/-1 0.03鍍錫銅,銅箔膠帶,pet膠帶 od=0.39

1354rf就要看你的規(guī)格了!

jollyzhong --- 2007-06-23 17:15:19

5

UNDERWRITERS LABORATORIES INC.           APPLIANCE WIRING MATERIAL

Subject 758   Section 1   Page 1354 Issued: Feb. 19, 1964

                                    Revised: Aug. 18, 1998

 

 

Style 1354

 

Coaxial Cable.

 

 

Rating

 

60°C or 80°C, 30 V.

 

 

 

Conductors

 

No. 44 AWG min, material not specified.

 

 

 

Insulation

 

2 mils min at any point, 125 mils max, Solid or Cellular PE, FRPE, Polypropylene, PFA, FEP, ECTFE, PTFE, ETFE or combination thereof with or without irradiation.  The insulation may be tape wrapped solid or cellular PTFE applied directly over the conductor or applied as a spiral wrapped Polyethylene thread (5 mils min, 40 mils max) and enclosed with “tubed on” insulation.

 

 

 

Covering

 

Optional - Extruded PVC Polyethylene or Irradiated Polyethylene, or PFA, or Polyester film.  Thicknesses not specified.

 

 

 

Shield

 

Page 24, required if outer shield is not provided.

 

 

 

Covering

 

Optional - Extruded PVC, or PFA, or heat sealed PVC tape, Polyamide Polyester, Kynar, FEP or PTFE, ECTFE, Tefzel, or lacquered braids, or tape wrapped PTFE Polyester film or Polyester-Polyethylene laminated film.  Thicknesses not specified.

 

 

 

Outer Shield

 

Page 24, (optional if inner shield is provided).

 

 

 

 

 

*

 

Outer Covering

 

Optional (required if outer shield is provided) - Extruded PVC, or PFA, or heat sealed PVC tape, Polyamide, Polyester, Kynar, FEP, PTFE, ECTFE, Tefzel, irradiated PE, irradiated PVC Polyurethane, or lacquered braid, thicknesses not specified.

 

 

 

Standard

 

UL 1581, Reference Standard for Electrical Wires Cables, and Flexible Cords.

 

(Continued on Page 1354A)
UNDERWRITERS LABORATORIES INC.           APPLIANCE WIRING MATERIAL

Subject 758   Section 1  Page 1354A Issued: Feb. 19, 1964

                                    Revised: April 24, 1992

 

 

 

Instructions

to UL

Representative

 

 

Detailed examination.

 

 

UL Counter-Check Program

 

 

(4) Detailed Examination.

(4) Horizontal Flame Test - Page 31.

 

 

Marking

 

General, Page 13.

 

 

 

Use

 

Internal wiring of Class 2 Circuits of Electronic Equipment or as insulated single in jacketed multiconductor cables.

 

Elva --- 2007-06-29 16:02:06

6

多謝謝

jollyzhong

michael --- 2007-06-29 18:31:25

7

四樓的規(guī)格全都正確,與HSD的非常接近。
gfren --- 2007-07-03 22:56:07

8

查UL規(guī)格書不就行了?

qwqzhw --- 2010-12-06 16:51:55

9

很簡單的東西,參考style page就好了

liwanjun926 --- 2010-12-24 20:32:46

10

樓主不 錯!

 

-- 結束 --