[問(wèn)題求助] 請(qǐng)問(wèn)有USB2.0 線的資料嗎?參照UL哪個(gè)標(biāo)準(zhǔn)做的?

P:2006-09-26 09:10:02

1

謝謝!

index - 指數(shù);指標(biāo);索引 (0) 投訴

P:2006-09-26 09:31:31

2

你的制作依據(jù)是USB協(xié)會(huì)規(guī)范?梢詤⒄誙L2725、2835、20276等

GPPS - general-purpose polystyrene通用聚苯乙烯 (0) 投訴

P:2006-09-27 08:51:04

3

0USB2.0測(cè)試規(guī)格.pdfUSB2.0測(cè)試標(biāo)準(zhǔn)

Physical Properties of Insulation and Jacke - 絕緣和護(hù)套的物理性能 (0) 投訴

P:2006-09-27 11:27:10

4

我那有個(gè)USB2.0的行業(yè)標(biāo)準(zhǔn),不知是否對(duì)你有幫助

HPFS - high-performance file system高性能文件系統(tǒng) (0) 投訴

P:2006-09-27 11:51:00

5

文件太大,上傳不了,郁悶

SIMOD - silicon fiber optic modulator硅光纖調(diào)制器 (0) 投訴

P:2006-11-08 11:10:05

6

有MICRO-USB資料嗎?

THF - tetrahydrofuran四氫呋喃 (0) 投訴

P:2006-12-18 10:55:36

7

看不到

solid/foam skin - 實(shí)心-泡沫皮 (0) 投訴

P:2007-01-05 10:36:37

8

大家好.

請(qǐng)問(wèn)有誰(shuí)知道USB協(xié)會(huì)的聯(lián)系方式?

non-migratory - 非移性<UL> (0) 投訴

P:2007-01-05 16:46:06

9

直接上USB協(xié)會(huì)網(wǎng)站www.usb.org ,國(guó)內(nèi)如果要搞USB認(rèn)證直接找臺(tái)灣ETC,我去年剛搞過(guò)

high-speed telephone rewind system - 高速電話線復(fù)繞系統(tǒng) (0) 投訴

P:2007-10-16 16:52:58

10

USB2.0的電線結(jié)構(gòu)和傳輸特性的標(biāo)準(zhǔn)是在USB2.0規(guī)范上的,但在USB2.0的規(guī)范上并沒(méi)有規(guī)定符合那個(gè)安規(guī),一般情況下我們是依UL規(guī)范做的,因?yàn)閁SB2,0的結(jié)構(gòu)按UL758標(biāo)準(zhǔn)對(duì)號(hào)入座的話有2725,20276,20379等等很多,有的廠家還用2835,所以這個(gè)并沒(méi)有定論,要看你客戶的要求了.

guy - 拉線,天線拉線 (0) 投訴

P:2007-11-11 12:07:57

11

skirt - shed (0) 投訴

P:2007-11-26 12:23:20

12

就是2樓回答的

low pressure steam - 低壓力蒸汽 (0) 投訴

P:2007-11-30 15:52:27

13

USB2.0 的標(biāo)準(zhǔn)是要求TYPE CM(UL444) 的。 協(xié)會(huì)認(rèn)証好象也接受2725。

peiletiser - 切粒機(jī),制粒機(jī),切片機(jī) (0) 投訴

P:2008-04-28 12:56:08

14

UNDERWRITERS LABORATORIES INC.              APPLIANCE WIRING MATERIAL

Subj. 758     Section 2     Page 2725        Issued:  1975-05-02

                                Revised:  2003-04-04

 

Style 2725    Electronic Cable.

______________________________________________________________________________

 

Rating     60°C or 80°C, 30 V.

______________________________________________________________________________

 

Insulated     Labeled or Complies with manufacturer's AWM Procedure.

Singles       May include mixed sizes.

______________________________________________________________________________

 

Conductor     Two, three, or four parallel, or two or more Assembly

           twisted insulated singles or groups of twisted singles

           twisted together or groups of twisted singles may be laid

           parallel to form flat or oval cable.  Lay not specified

           barrier layer and/or fillers optional.  Manufacturer shall

           maintain a complete description of each assembly.  Diameter

           of assembly under jacket one inch maximum.

______________________________________________________________________________

 

Shield     Optional.

______________________________________________________________________________

 

Jacket     PVC, Class 43, 9 mils minimum average, 7 mils minimum at

           any point.

______________________________________________________________________________

 

Standard      Appliance Wiring Material UL 758.

______________________________________________________________________________

 

Instructions  Detailed Examination.

to UL

Representative

______________________________________________________________________________

 

UL         (4)  Detailed Examination.

Counter-Check (4)  Flexing.

*Program      (12) Horizontal Flame Test.

______________________________________________________________________________

 

Marking       General.

______________________________________________________________________________

 

Use        Internal wiring of electronic equipment in Class 2 systems

           only.

HSTU unit - 高速收線裝置 (0) 投訴

P:2008-04-28 12:57:10

15

UNDERWRITERS LABORATORIES INC.                     APPLIANCE WIRING MATERIAL

Subj. 758        Section 2        Page 2835        Issued:  1976-10-28

                                                  Revised:  2003-01-03

 

Style 2835

 

PVC Jacketed Cable.

 

Rating

 

 

60°C, 30 V.

 

Conductor

 

 

40 AWG minimum.  Material not specified.

 

Insulated

Singles

 

 

Material not specified for use statement 1A or 1B.  Labeled or complies with manufacturer's Procedure for use statement 2A or 2B.

 

 

Assembly

 

 

Consists of two or more conductors, twisted pairs, or groups of twisted conductors.  The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction.  Lay not specified.  Barrier layer and/or fillers optional. May use same or mixed AWG sizes.  Manufacturer shall maintain a complete description of each assembly.

 

 

Covering

 

 

Optional.  PVC, 5 mils minimum at any point, over the assembly or groups of singles.

 

 

Shield

 

Optional.  May be over one or more of the  insulated conductors or applied over the assembly.

 

 

Jacket

 

 

 

 

 

 

 

 

*

*

 

 

PVC - Class 43.

 

If parallel construction is rippable, the measurements are made after ripping.

 

  Dia# of Cable

  under Jacket               Minimum        Minimum

   in inches              Average (mils)  at any point

 

0.250 or less (1A,2A only)      15             13

0.250 or less (1B,2B only)      30             27

0.251 - 0.424                   30             27

0.425 - 0.700                   60             48

0.701 - 1.500                   80             64

1.501 - 2.500                  110             88

2.501 or larger                140            112

 

# = Major diameter if flat or oval construction.

 

                            (Continued on Page 2835A)

 

 


UNDERWRITERS LABORATORIES INC.                      APPLIANCE WIRING MATERIAL

Subj. 758        Section 2        Page 2835A        Issued:  1976-10-28

                                                   Revised:  2003-01-03

 

 

Standard

 

 

Appliance Wiring Material UL 758.

 

Instructions

to UL

Representative

 

 

Detailed Examination.

 

UL

Counter-Check

Program

 

 

(4)  Detailed Examination.

(4)  Flexibility Test.

(12) Cable Flame Test on Completed Cable, External Use,

     Constructions 1B and 2B.

(12) Horizontal Flame Test on Completed Cable Internal

     Use, Constructions 1A and 2A.

 

 

Marking

 

 

General.

 

 

Use No. 1A

 

 

Use No. 1B

 

 

 

 

Use No. 2A

 

 

 

Use No. 2B

 

Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.

          

CABLES - using 30 mils or greater jacket thickness only:  External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.

 

Internal wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.

          

CABLES - using 30 mils or greater jacket thickness only:  External interconnection or internal wiring in Class 2.

 

 

 

stranding lay length - 絞距,絞合節(jié)距 (0) 投訴

24


你需要登錄才能發(fā)表,點(diǎn)擊登錄。