7
| UNDERWRITERS LABORATORIES | APPLIANCE WIRING MATERIAL | ||||
| Subj.758 | Section 1 | Page 10453 | Issued:1999-10-13 |
| Revised:2008-05-27 | |||
| Style 10453 | Coaxial Cable. | |
| Rating | 60, 80, 90, 105 deg C, 30 Vac, Horizontal flame. |
| Conductor | 28 AWG - 12 AWG solid or stranded round, tinned or bare copper. |
| Insulation | PVC, 5 mils min average, 4 mils minimum at any point. |
| Assembly | Core may be either flat or round. Barrier layer and/or fillers optional. |
| Shield | Optional. One or more. |
| Covering | Optional. PVC, 7 mils minimum average, 6 mils minimum at any |