美女胸被狂揉扒开吃奶的网站o_亚洲日韩av中文无码专区_东京热激情无码专区_久久HEZYO久综合亚洲色_欧美成人高清视频_国产精品乡下勾搭老头_欧美一级v片在线播放_成人午夜国产视频_男女猛烈无遮挡免费动态图_亚洲一区国产精品视频

首頁 > 國外線纜

[問題求助] UL2468是否要測試導(dǎo)體中心距和撕裂厚度?

P:2007-12-10 09:57:04

1

UL2468是否要測試導(dǎo)體中心距和撕裂厚度?查標(biāo)準(zhǔn)哪條?

OFCL - optical fiber communication line光纖通信線路 (0) 投訴

P:2007-12-10 11:00:03

2

結(jié)構(gòu)測試查STYE PAGE上面,不過以前做過沒有要求做間距和撕裂后最小厚度,STYE PAGE上面沒有做這方面要求吧!

cotton-insulation cable - 紗包電纜,紗包絕緣電纜 (0) 投訴

P:2007-12-10 13:53:04

3

我也是第一次聽說,以前做了很多也沒做過,檢查的人說這個(gè)線類似SPT電源線,所以參照UL62做,可是我這個(gè)是758,按照那個(gè)做沒道理啊,郁悶!

injection pressure - 注塑壓力 (0) 投訴

P:2007-12-10 21:35:46

4

UL2468  測試導(dǎo)體中心距和撕裂厚度我們以前列入了公司產(chǎn)品檢驗(yàn)標(biāo)準(zhǔn)里面,UL 758 里面好象沒有這一條規(guī)定。是客戶提出來以后加上去的,具體的參照哪個(gè)標(biāo)準(zhǔn)我也想學(xué)習(xí)了解。

hairpin type furnace - 夾叉式退火或淬火爐 (0) 投訴

P:2007-12-11 13:48:16

5

我們生產(chǎn)的UL2468也沒做過這方面的測試.我也想學(xué)習(xí)一下,

self-healing - 自愈(意指網(wǎng)絡(luò)在局部失效后,無需人為干預(yù),能自動(dòng)選擇替代路由,重新配置業(yè)務(wù),并能恢復(fù)通信能力) (0) 投訴

P:2007-12-11 13:55:33

6

標(biāo)準(zhǔn)中是沒有,但一般客戶都有要求的.

thermosetting plastic - 熱固塑料,熱固性塑料 (0) 投訴

P:2007-12-19 09:25:50

7

可是我現(xiàn)在不是客人,而是UL

Zinkalium - 津卡合金(一種鋅鋁合金,含Zn 12%,Cu 3%,Al85%) (0) 投訴

P:2007-12-19 16:48:50

8

UL人員對標(biāo)準(zhǔn)的理解也不怎么深入!經(jīng)常出錯(cuò)誤!

peroxide cross-linking - 過氧化物交聯(lián) (0) 投訴

P:2007-12-28 17:09:52

9

有誰可以幫忙指出應(yīng)該按照UL62什么標(biāo)準(zhǔn)嗎?

forked tube - 三通管 (0) 投訴

P:2009-06-06 18:24:06

10

UL人員經(jīng)常出錯(cuò),玩弄國人。

repeaterless submarine optical cable - 無中繼海底光纜,無增音機(jī)海底光纜 (0) 投訴

P:2009-06-09 11:06:34

11

中心距還不就是最小絕緣厚度的影響嗎?

parallel connection - 并聯(lián) (0) 投訴

P:2009-06-16 13:45:32

12

UNDERWRITERS LABORATORIESAPPLIANCE WIRING MATERIAL
Subj.758Section 2Page 2468Issued:1968-05-07
Revised:2008-05-27
Style 2468Flat Ribbon cable.

Rating80 deg C, 300 Vac, Horizontal flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor32 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPVC, 15 mils min average, 13 mils minimum at any point.
AssemblyTwo to one hundred and fifty conductors laid parallel and in one plane. Same or mixed AWG. Each conductor has a nominal 15 mils or heavier wall. This forms a flat cable with a single row of conductors having a 1/2 in. maximum width web between insulated conductors.
ShieldOptional.
Covering(Optional) PVC, 5 mils min. at any point 80 mils max
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Appliances; or internal wiring of Appliances where exposed to oil at a temperature not exceeding 60 deg C or 80 deg C, whichever is applicable.

各位,按照最新的AWM2468的Style Page,中心距不能大于1/2inch,絕緣為15/13mil,壁厚為15mil,(之前的版本要求撕裂后的厚度為15/13mil,不過現(xiàn)在取消了此要求)。本人就是一名UL檢驗(yàn)員,希望大家給點(diǎn)面子,有問題可以提出來進(jìn)行交流學(xué)習(xí)!謝謝

high productivi,ty reel handling machinery - 高效率線盤運(yùn)輸機(jī) (0) 投訴

P:2009-10-26 16:06:07

13

標(biāo)準(zhǔn)中是沒有

anneal - 退火,軟化,韌煉,老煉。將導(dǎo)體加熱后,再經(jīng)過冷卻,減輕其機(jī)械應(yīng)力,即所謂「退火」或「軟化」,鍚線經(jīng)過退火后,較為柔軟。 (0) 投訴

13


你需要登錄才能發(fā)表,點(diǎn)擊登錄。